APNT-150 - Standard 2-Way Lighting Circuit (with Neutral) using Qubino Flush Dimmer Plus

IMPORTANT - Read this first!

Note: To simplify these diagrams, we have not shown the earth cables - but all circuits MUST have the earth cable correctly installed.

We've shown wires in red to indicate that they are new wires, but it doesn't really matter what colour you use.

To protect the module a suitable rated overcurrent protection fuse must be installed on the Live input.

We work hard to keep these wiring guides accurate and up to date and would appreciate any feedback, corrections or suggestions that you may have. Please contact us using our help page or by simply emailing feedback@vesternet.com

 

One of the things that confuses people the most is installing home automation into an existing 2-Way lighting system. This application note looks at how a Qubino Flush Dimmer Plus module can be installed to control a Standard 2-Way Lighting Circuit with Neutral available.

Firstly, what do we mean by 2-Way lighting?

This simply refers to a lighting system where one light is controlled by two light switches. Examples of this are where a room has two entrances (each needs a light switch) or for a hall light that can be controlled from the hall and the upstairs landing.

More information about 3-Wire lighting systems is available in APNT-23: Understanding 2-wire and 3-wire Lighting Systems.

For information on how to physically install a Z-Wave module take a look at our guide here.

To know more about how Z-Wave modules work with different switch types make sure to read our guide here.

Standard 2-Way Lighting Circuit (with Neutral)

Standard 2-Way Wiring System (with Neutral) Figure 1: Standard 2-Way Lighting Circuit (with Neutral).

2-Core cables (brown and blue) carries Live and Neutral to the wall switch and Switched Live and Neutral up to the light fitting. An extra 3-Core cable (brown, black and grey) connects the two wall switches together, enabling each of them to independently turn the light On or Off.

This type of lighting system uses "Toggle" (latching) switches. These latch in position - for instance when you press the switch to On, the switch physically stays in the On position. These are the standard light switches you'll find already fitted in your home.

The module can also be used with a variety of "Momentary" switch types and configurations. Momentary switches, also known as Retractive or Bell-Push, only remain in the On state while you press them, they return to the Off state when the button is released.

More information about how the Qubino Flush Dimmer Plus works with different switch types is available here.

We can install the module into this 2-Way circuit in various different ways shown below. We've separated out the diagrams based on whether you need to install the module at Switch A or Switch B position.

Qubino Flush Dimmer Plus Connections

The Qubino Flush Dimmer Plus has six terminals to connect it to the electrical wiring:

Qubino Flush Dimmer Plus Connections

 

  • I1 – connection to Switch 1
  • I2 – connection to Switch 2
  • I3 – connection to Switch 3
  • ~ (Output) – connected to light or load
  • L – Live
  • N – Neutral

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters may need to be set:

  • 1 - 0 - enables the module to work with momentary switch (default)
  • 1 - 1 - enables the module to work with a toggle switch
  • 20 - 1 - enables the modules' I2 switch to also control the load (default 0)

Installation at Switch A position

This is probably the most common of requirements, you will install the module at the Switch A position where it has access to both the 2-Core wires and the 3-Core wire.

 

Toggle Switches

To retain your existing standard Toggle switches, we can simple install the module as shown in Figure 2.

2-Way Wiring with Toggle Switches (Switch A) Figure 2: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Toggle switches.

In this case we keep the standard Toggle switches connecting "L1" to the module's I1 input with the "L2" wire connected to Live. Live and Neutral are wired to L and N terminals respectively.

This gives simple On / Off control of the light from the switches but you will still be able to control the dimming level over Z-Wave if required.

 

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 1 - enables the module to work with a toggle switch (default is 0 for a momentary switch)

 

Toggle Switches - Alternate

Another option to use standard Toggle switches is to install the module as shown in Figure 3.

2-Way Wiring with Toggle Switches (Switch A) Figure 3: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Toggle switches.

In this case we keep the standard Toggle switches connecting Switch A "L1" to the module's I1 input and Switch B "L1" to the module's I2 input with the "COM" wire connected to Live. Live and Neutral are wired to L and N terminals respectively.

Any unused wires from the original 3-core between the two switches should be safely terminated.

The module is then configured to accept I2 as the second switch control of the module.

This gives simple On / Off control of the light from the switches but you will still be able to control the dimming level over Z-Wave if required.

 

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 1 - enables the module to work with a toggle switch (default is 0 for a momentary switch)
  • 20 - 1 - enables the modules' I2 switch to also control the dimmer (default 0)

 

Momentary Switches

For full On / Off and dimming control we can replace the Toggle wall switches with similar styled Momentary switches.

 

2-Way Wiring with Momentary Switches (Switch A) Figure 4: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Momentary switches.

By using Momentary switches, the 2-Way wiring can be simplified - simply connect both Switch A and Switch B "L1" to the module's I1 input and the "COM" wire to Live. Live and Neutral are wired to L and N terminals respectively.

Any unused wires from the original 3-Core between the two switches should be safely terminated.

 

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 0 - keep as default to work with a momentary switch

 

Multi-Way install with Momentary Switches

Using the module with Momentary switches enables the easy creation of 3-Way lighting circuits, in fact an infinite number of Momentary switches can be wired in parallel to create 3-, 4-, 5-, 6-way... lighting systems.

Multi-Way Wiring with Momentary SwitchesFigure 5: Multi-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Momentary Switches.

Simply add on as many Momentary switches as you require by extending the "L1" and "COM" wires. Any unused wires from the original 3-Core between the switches should be safely terminated.

 

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 0 - keep as default to work with momentary switch

 

Multi-Way with Z-Wave Wall Switch

Sometimes you may require a 2-Way or multi-way lighting circuit where physical wiring doesn't already exist, or perhaps you need to re-purpose the existing wiring for something else.

Z-Wave makes this possible using something known as "Associations" - where one Z-Wave device can control another Z-Wave device directly without inter-connecting wiring. More information on Associations can be seen in our guides here and here.

2-Way with Z-Wave Wall SwitchFigure 7: Using Z-Wave Switches in a Standard 2-Way Lighting Circuit (with Neutral) with Qubino Flush Dimmer Plus.

To create this circuit you simply install the module to suit either Toggle or Momentary switches and safely terminate the 3-Core cable as required. A battery powered Z-Wave Wall Controller can then be Associated to the module.

Don't forget to configure the module for Toggle or Momentary switches!

Installation at Switch B position

In some circumstances it may not be possible to install the Qubino Flush Dimmer Plus module at the Switch A position - perhaps there's not enough room physically to install it there, or perhaps that position is out of range of the Z-Wave netwok. In this case sometimes it's possible to install at the Switch B position but there are a number of caveats because in this position it won't have access to both the 2-Core and 3-Core wires.

 

Toggle Switches - add additional wire between switches

To retain your existing standard Toggle switches, we can install the module as shown in Figure 9.

Note: An additional wire is required to be run between the switch positions to be used as Neutral and Switched Live!

2-Way Wiring with Toggle Switches (Switch B)Figure 8: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Toggle switches at Switch B location.

In this case we keep the standard Toggle switches, connecting Switch A "L1" to the module's I1 input and Switch B "L1" to the module's I2 input with the "COM" wire connected to Live. We use the original "L2" wire to bring over Neutral from the first switch position and an additional wire is added to take Switched Live back to Switch A position.

The module is then configured to accept I2 as the second switch control of the module.

This gives simple On / Off control of the light from the switches but you will still be able to control the dimming level over Z-Wave if required.

 

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 1 - enables the module to work with a toggle switch (default is 0 for a momentary switch)
  • 20 - 1 - enables the modules' I2 switch to also control the dimmer (default 0)

 

Momentary Switches - add additional wire between switches

For full On / Off and dimming control we can replace the Toggle wall switches with similar styled Momentary switches.

Note: An additional wire is required to be run between the switch positions to be used as Neutral and Switched Live!

2-Way Wiring with Momentary Switches (Switch B)Figure 9: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Momentary switches at Switch B location.

Here we replace the standard Toggle switches with Momentary switches and connect both Switch A and Switch B "L1" to the module's I1 input and the "COM" wire to Live. We use the original "L2" wire to bring over Neutral from the first switch position and an additional wire is added to take Switched Live back to Switch A position.

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 0 - keep as default to work with momentary switch

 

Toggle Switches - re-wire Neutral and Switched Live to Switch B

2-Way Wiring with Toggle Switches (Switch B)Figure 10: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Toggle switches at Switch B location.

Connect Switch A and Switch B “L1” to the module's I1 with the "L2" wire connected to Live. Re-wire Neutral and Switched Live to the Switch B position.

This gives simple On / Off control of the light from the switches but you will still be able to control the dimming level over Z-Wave if required.

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 1 - enables the module to work with a toggle switch (default is 0 for a momentary switch)

 

Toggle Switches - re-wire Neutral and Switched Live to Switch B (Alternative)

2-Way Wiring with Toggle Switches (Switch B)Figure 11: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Toggle switches at Switch B location.

Connect Switch A “L1” to the module's I1 and Switch B "L1" to the module's I2 input with the "COM" wire connected to Live. Re-wire Neutral and Switched Live to the Switch B position.

The module is then configured to accept I2 as the second switch control of the module. Any unused wires from the original 3-core between the two switches should be safely terminated.

This gives simple On / Off control of the light from the switches but you will still be able to control the dimming level over Z-Wave if required.

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 1 - enables the module to work with a toggle switch (default is 0 for a momentary switch)
  • 20 - 1 - enables the modules' I2 switch to also control the dimmer (default 0)

 

Momentary Switches - re-wire Neutral and Switched Live to Switch B

2-Way Wiring with Momentary Switches (Switch B)Figure 12: Standard 2-Way Lighting Circuit (with Neutral) using the Qubino Flush Dimmer Plus with Momentary switches at Switch B location.

Here we replace the standard Toggle switches with Momentary switches and connect both Switch A and Switch B "L1" to the module's I1 input and the "COM" wire to Live. Re-wire Neutral and Switched Live to the Switch B position.

Any unused wires from the original 3-core between the two switches should be safely terminated.

Qubino Flush Dimmer Plus Parameter Setting:

The following parameters need to be set:

  • 1 - 0 - keep as default to work with momentary switch

 

2-Way with Z-Wave Wall Switch

2-Way with Z-Wave Wall SwitchFigure 13: Using a second Qubino Flush Dimmer Plus I2 input in a Standard 2-Way Lighting Circuit (with Neutral) with Qubino Flush Dimmer Plus.

Here we replace Switch A with a Z-Wave Wall Switch. Connect Switch B “L1” to the module's I1 input with the "COM" wire connected to Live. We use the original "L1" wire to bring over Live from the first switch position, “L2” to take Switched Live and "COM" to take Neutral back to Switch A position. Any unused wires from the original 3-core between the two switches should be safely terminated.

A battery powered Z-Wave Wall Controller can then be Associated to the module. More information on Associations can be seen in our guides here and here.

 

Install at Switch B and use I2 from Qubino Flush Dimmer Plus at Switch A

2-Way with Z-Wave Wall SwitchFigure 14: Using Z-Wave Switches in a Standard 2-Way Lighting Circuit (with Neutral) with Qubino Flush Dimmer Plus.

Here we connect Switch A “L1” to Module A I2 input. Connect Switch B “L1” to the Module B I1 input with the "COM" wire connected to Live. We use the original "L1" wire to bring over Live from the first switch position, re-wire “L2” to take Switched Live and "COM" to take Neutral back to Switch A position. Any unused wires from the original 3-core between the two switches should be safely terminated.

More information on how to use a Secondary Switch with a Qubino Flush Dimmer Plus module can be found here.

Note: power to module at Switch A not shown as this would typically be taken care of for switching the other gang in a 2-gang switch.