Z-Wave Fibaro Universal Dimmer 2 Q&A
Activity timeframe
I have 18 LEDs at 5w and 0.5 power factor. Would I be able to use the Dimmer 2 if were to use alongside the Bypass 2 or is the wattage too high? Based on the technical resources I think it would overload it but I have seen some responses to questions saying this number of bulbs should be fine. View answer
Asked 6 ´years ago
Can Fibaro Dimmer 2 independently dim 2 circuits? View answer
Asked 1 ´year ago
We are rewiring the house and as part of this will have a neutral at each switch. Two questions I have are 1) for loads less than 50W is a bypass still required even in a 3 wire setup? 2) is there a cheaper alternative to the fibaro which still offers smooth LED dimming? Thanks. View answer
Asked 4 ´years ago
Would there be a minimum GU10 number of lights that would not need a Fibaro dimmer 2 ? I have a number of circuits with GU10 lights 6W X 9 in a kitchen and out in a hallway 2 way circuits of 2 each by 2 and a circuit of 4. Would I need a dimmer bypass then for all circuits. View answer
Asked 7 ´years ago
Will this be usable as a on/off toggle for Fluorescent tube lights? View answer
Asked 8 ´years ago
When using the Dimmer 2 in a 2-way or multi-way circuit, do the momentary (bell-push) switches need to be 2-way switches or will 1-way switches work? (as the wiring is simplified when using momentary switches). Such as the Varilight 2-Gang 6A 1-Way Push-to-Make Momentary Switch? Thanks View answer
Asked 6 ´years ago
is this a USA frequency or EU? View answer
Asked 8 ´years ago
I look at the instruction manual for the wiring diagrams. I have two wires coming from the wall and it has no wall switch. When I moved in, it had a cheap strip light with shaver socket and its own onboard switch. I have removed this old fitting. I am planning to install an LED strip light running off 12V. I wish to use the Fibaro Dimmer 2 with bypass 2. When I look at the wiring diagram for a 2 wire setup, it assumes I will have a Wall Switch. This makes the diagram useless to me. Can anybody help with an adjusted diagram please? View answer
Asked 8 ´years ago
I am currently using these with 240v halogen bulbs and wanted to switch to LED. In some places it will be 3 wired and in others I will add a bypass unit. Is there any particular brands of dimmable 240v LED bulbs that people have had success or problems with? Or am I pretty safe just going with shop own brand? They would be either E27 golfball bulbs or gu10 spots View answer
Asked 6 ´years ago
How do these cope installed in metal back boxes in a brick wall? I was considering installing these in the ceiling with the light fitting, but with some of the wire configurations i have here, i will need to install deeper metallic back boxes and install behind the switches. View answer
Asked 8 ´years ago
Hi! This dimmer operate in Europe frequency range? Thanks View answer
Asked 5 ´years ago
Hi All After years of trying to find a good zwave remote control I think I might have hit on a good (crazy) idea. Would this module work behind a light switch if there was no output load to control ? My plan is to use something like this https://www.ukelectricalsupplies.com/retrotouch-07100-simplicity-white-2-gang-retractive-light-switch.htm, so i should get the ability to control four scenes, using s1 and s2 Would I be correct that it will work with out a light to control. Thanks Rob View answer
Asked 4 ´years ago
How many 240V GU10 Led Bulbs (Dimmable ones) can the FD2 support? I have 3 light fittings for outside my house that house 2 GU10 240 Bulbs or GU10 240V Dimmable Bulbs. I am going to use the LED Dimmable bulbs which on the box say "Use only 7 watts per bulb". So a total of 6 bulbs in 3 light housings. I'm going to wire them back to a junction box in parellel (not serial) and into then into the FB2 but was worried that 6 bulbs of this type (or even 10) would fry it? I have the original Fibaro Bypass Module also (FGB001) which I bought a few years ago but never used, could I use this if I need it? The LED 240v GU10 bulbs are "dimmable" Thanks! Andy View answers
Asked 7 ´years ago
Does this work with homeseer hs3? View answers
Asked 8 ´years ago