I am currently using these with 240v halogen bulbs and wanted to switch to LED. In some places it will be 3 wired and in others I will add a bypass unit. Is there any particular brands of dimmable 240v LED bulbs that people have had success or problems with? Or am I pretty safe just going with shop own brand? They would be either E27 golfball bulbs or gu10 spots View answer
Asked 6 ´years ago | Z-Wave Fibaro Universal Dimmer 2
Asked 6 ´years ago | Z-Wave Plus Aeotec Clamp Power Meter - One Clamp (60A)
I'm trying to use this switch to control load by both S1 and S2 (connected to separate switch), but it my case switch connected into S2 has no impact on the load. I had no problem with achieving the same effect with Everspring module AN179, but somehow it does not work with Fibaro. Have anyone has achieved such configuration (controlling load by both S1 & S2)? View answer
Asked 6 ´years ago | Z-Wave Fibaro Single Switch 2
Does this module work with Fibaro? View answers
Asked 6 ´years ago | Yale Smart Living Z-Wave Module 2
is this z-wave plus ?? View answer
Asked 6 ´years ago | Yale Smart Living Z-Wave Module 2
I was seriously thinking about buying one of these for a house I am buying off plan but put off by the fact that this cannot be installed in direct sunlight and needs to be protected from rain. How can this be used as an external door entry system if it can’t be used outside? Also, with the camera, can I hook this up to an NVR to record the live stream like a CCTV camera? If the above can be confirmed, that would be great! Thanks, Hal View answer
Asked 6 ´years ago | Fibaro Intercom
If you were using 3-position (on/off/on) switches would you need 3core+ earth cable running between all switches in a 2-way or multi-way lighting circuit? or could this be achieved with 2 core+earth cable between switches? thanks View answer
Asked 6 ´years ago | Z-Wave Fibaro Universal Dimmer 2
When using the Dimmer 2 in a 2-way or multi-way circuit, do the momentary (bell-push) switches need to be 2-way switches or will 1-way switches work? (as the wiring is simplified when using momentary switches). Such as the Varilight 2-Gang 6A 1-Way Push-to-Make Momentary Switch? Thanks View answer
Asked 6 ´years ago | Z-Wave Fibaro Universal Dimmer 2
I bought this motion sensor and tried without success to include to my new smartthings hub v2 (UK version). Smartthings support advised me to confirm that the motion sensor is also a UK version (not a US one), as apparently the frequencies are different... Can you please confirm that this sensor works with the UK version of smartthings hub? View answers
Asked 6 ´years ago | Z-Wave Fibaro Multi Sensor
I have a fused Switch controlling a fan and want to use this controller to operate the fan remotely as well as enabling the fused switch to continue controlling the fan at the wall, is there a wiring diagram showing how to achieve this? View answers
Asked 6 ´years ago | Z-Wave Plus Aeotec Nano Switch On/Off Controller
Hi. Has anyone had a good experience with these? The concept is great, but not if it doesn't work! Is it the firmware that is unstable, or the controller software? Have the Vesternet staff had any experience with them? Also, are they always listening, or do they have a wake up period? Thanks, Ed View answers
Asked 6 ´years ago | Contrôleur de chaleur Fibaro Z-Wave Fibaro
I have a Homeseer setup and have bought the Fibrao FGS 223. I have managed to include it but want to change the default toggle to momentary switch as that's what I have elsewhere [legacy X10]. I tried Setting Parameter 20 to 0 in homseer z-wave node but it just says error and dosent change. Any help please View answer
Asked 6 ´years ago | Z-Wave Fibaro Double Switch 2
Hi There. I'm confused how the heat controller on each Rad will "call" for heat on a standard UK boiler system. Surely there needs to be something on the boiler end to call the heat when the radiator valve asks for it? View answer
Asked 6 ´years ago | Pack de démarrage de thermostat de radiateur de radiateur Z-Wave Fibaro
Hi Folks. Is it feasible to use this sensor to control your central heating. If I used a fibaro relay to control the boiler could the temperature sensor be used as a thermostat to set or monitor the temperature or would I need to buy a dedicated Zwave thermostat? Any advice would be greatly appreciated. View answer
Asked 6 ´years ago | Z-Wave Fibaro Multi Sensor
Asked 6 ´years ago | Z-Wave Philio Motion Capteur PSP05 avec recesseur rond - GEN5
Does it disconnect the neutral line as well ? View answer
Asked 6 ´years ago | Z-Wave Plus Secure Wall Switch
This installed with 4 SES002 and paired to Vera Edge. Vera reports the correct ambient temp agains the first sensor but all 4 pipe sensors report "-327.68 °". Ive checked all the connections, removed and reattached from the Zwave network etc but stays same. What can you suggest pls View answers
Asked 6 ´years ago | Z-Wave Plus Secure SES302 Temperature Sensors Gen5
How does the thermostat in a room that is too cold turn the boiler on so that the radiator can be supplied with hot water. You can’t leave the boiler set on permanently. In most UK central heating systems there is a central thermostat and or programmer that determines when the boiler switches on or off. View answers
Asked 6 ´years ago | Contrôleur de chaleur Fibaro Z-Wave Fibaro