I used these in the past with LED power supplies but unfortunately even though the static current was under 1 amp, after a while the power supply inrush current would weld the relay contacts closed. I put a thermistor in-line with the load to limit the inrush and Qubino said they were aware of this and working on a solution. Does anyone know if this problem has been fixed?
Z-Wave Qubino Flush Relay x 2 Plus
I used these in the past with LED power supplies but unfortunately even though the static current was under 1 amp, after a while the power supply inrush current would weld the relay contacts closed. I put a thermistor in-line with the load to limit the inrush and Qubino said they were aware of this and working on a solution. Does anyone know if this problem has been fixed?
New Qubino Flush Relay Plus - Z-Wave Plus with new features The Qubino Flush 2 Relay Plus is a two channel Z-Wave switch capable of controlling two independent appliance or light circuits up to a maximum load of 4A each. It fits into an existing light switch enabling you to wirelessly control a...
See More
New Qubino Flush Relay Plus - Z-Wave Plus with new features The Qubino Flush 2 Relay Plus is a two channel Z-Wave switch capable of controlling two independent appliance or light circuits up to a maximum load of 4A each. It fits into an existing light switch enabling you to wirelessly control a...